Protects critical CE/IEC 60601-1 listed medical equipment in patient-care vicinities against damage, downtime and data loss due to blackouts, brownouts, power surges and line noise.

  • Corrects under- and overvoltages from 155V to 274V
  • 6 IEC-320 C13 outlets
  • Front-panel LEDs indicate load, power, voltage and battery statuses
  • Expandable runtime with optional external battery packs
  • 27.5 min. runtime at half load; 11 min. at full load

  • Kenmerken
  • Toepassingen
  • Accessoires
  • Bestelgegevens
  • Downloads
  • Provides AC output for electrical equipment in patient-care vicinities
  • Meets strict leakage requirements for medical equipment
  • Factory-muted alarm can be restored to signal loss of utility power, low battery or overload
  • 6 IEC-320 C13 outlets
  • 1.8 m power cord with C14 input
  • 480-joule surge suppression rating
  • Supports half load up to 27.5 min. and full load up to 11 min.
  • Internal batteries designed for hot-swap field replacement
  • Expandable runtime with optional external battery packs, such as Tripp Lite’s BP36V15-2U
  • Cold-start capability enables turn-on in battery mode during blackouts
  • Offers full line isolation and removes common mode noise while maintaining full AC surge suppression
  • Maintains 230V nominal output over input range of 155V–274V without using battery power
  • Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance
  • Front-panel LEDs indicate line power, battery power, overload, voltage regulation and battery status
  • USB and DB9 ports combine with included PowerAlert software to monitor operating conditions, monitor AC power, and enable safe unattended system shutdown and file saves in case of a prolonged power failure
  • Output Volt Amp Capacity (VA) 1000
  • Output Watt Capacity (Watts) 750
  • Nominal Output Voltage(s) Supported 220V; 230V; 240V
  • Nominal Voltage Details 230v nominal inverter output voltage
  • Frequency Compatibility 50 / 60 Hz
  • Frequency Compatibility Details : Automatic frequency selection
  • Output Voltage Regulation (Line Mode) -18%, +8%
  • Output Receptacles (6) C13
  • Output AC Waveform (Battery Mode) PWM sine wave